Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring

Product Details
Customization: Available
Application: Electronic, Instrument
Type: Current Transformer
Still deciding? Get samples of US$ 18/Piece
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (28)
  • Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
  • Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
  • Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
  • Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
Find Similar Products

Basic Info.

Model NO.
ECS36- Iw02
Phase
Single
Operation Condition
Indoor
Usage
Protection, Measurement
Winding Form
Single Layer & Tightly Wound Type
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Color
Black
Certification
UL & Ce
Regulation
RoHS
Transport Package
Carton
Specification
350g
Trademark
Echun
Origin
China
HS Code
8504500000
Production Capacity
5000PCS/Month

Product Description

Echun 300A/5A Current Ratio Split Core Current Transformer for Power Instrument & Protection
The ECS36 Series are split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation.
------------------------------------------------------------------------------------------------------------------------------------------
Product Parameter 
NO. 1. Electrical Specifications 
Rated Primary Current(Amp. ) 50/60Hz 300nom(1 ~ 360A max. )
Turn Ratio  Np: Ns= 1: 60
Current Ratio 300A/5A
D. C. Resistance at 20ºC (Ω) 125mΩ±10%
Accuracy @RL=10Ω 0.5%
Phase Error at Rated Current Range ≤1.0°%
Operating Temperature Range -40 ~ +70ºC
Storage Temperature Range -45 ~ +85ºC
Dielectric Withstanding Voltage 2.5KV/1mA/1min
Impluse Withstand Voltage 5KV Peak
Insulation Resistance DC500V/100MΩ min

 No. 2. Part Number 
Part Number Input  Current Available Output 
ECS36-100 100A Current Outputs/ 20mA, 33.3mA,40mA,50mA,100mA,1A,5A.   Voltage Outputs/ 0.25V,0.333V,0.5V,1V,2V.
ECS36-200 200A
ECS36-300 300A
ECS36-400 400A
ECS36-500 500A
ECS36-600 600A
NotesCurrent Ratio customised are Available. 
------------------------------------------------------------------------------------------------------------------------------------------
Structure & Dimensions
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring


------------------------------------------------------------------------------------------------------------------------------------------
Applications
       1. Current measurement
       2. Monitoring & protection
       3. Energy & sub-metering products
       4. Network equipment
       5. Instruments & sensors
       6. Control systems
    Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring
------------------------------------------------------------------------------------------------------------------------------------------
Related Prodcucts
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring

------------------------------------------------------------------------------------------------------------------------------------------
Company Profile
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring

------------------------------------------------------------------------------------------------------------------------------------------
Package & Transportation
Current Transformer 300AMP Input Low Power Consumption Hall Sensor for Energy Monitoring

------------------------------------------------------------------------------------------------------------------------------------------

How to contact:
  •  Echun Electronic Co. Ltd
  •  Address: 3rd floor,B Building, No.88,ShengYe Road, North TianMei,HuangJiang Town,   Dongguan, Guangdong, China  (523757)
  • Tel:  (86 769) 8360 8582
  • Fax:  (86 769) 8360 8337
  • Mobile:  (86) 155 2708 5032
  • Website: dgechun.en.made-in-china.com
-------------------------------------------------------------------------------------------------------------------------------------------
   Really appreciate that you browse our Products.
   Any question please let me know and contact to our online salesman.
  Your trust will be our best encourgement. Look forward to making a coorperation with you.

-------------------------------------------------------------------------------------------------------------------------------------------

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier