• Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
  • Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
  • Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
  • Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying

Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying

Application: Electronic, Instrument
Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Protection, Measurement
Winding Form: Single Layer & Tightly Wound Type
Samples:
US$ 18/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company
Diamond Member Since 2018

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (28)

Basic Info.

Model NO.
ECS36- Iw03
Insulating Medium
Insulating Paper
Installation
Active Type
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Color
White
Certification
UL & Ce
Regulation
RoHS
Transport Package
Carton
Specification
426g
Trademark
Echun
Origin
China
HS Code
8504500000
Production Capacity
5000PCS/Month

Product Description

Echun 400A/100mA Current Ratio Split Core Current Transformer for Power Instrument & Protection
The ECS36 Series are split-core current transformers. The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation.
------------------------------------------------------------------------------------------------------------------------------------------
Product Parameter 
NO. 1. Electrical Specifications 
Rated Primary Current(Amp. ) 50/60Hz 400nom(1 ~ 500A max. )
Turn Ratio  Np: Ns= 1: 4000
Current Ratio 400A/100mA
D. C. Resistance at 20ºC (Ω) 154Ω±10%
Accuracy @RL=10Ω 0.5%
Phase Error at Rated Current Range ≤15%
Protection Level 7.5 Vo peak
Operating Temperature Range -40 ~ +70ºC
Storage Temperature Range -45 ~ +85ºC
Dielectric Withstanding Voltage 2.5KV/1mA/1min
Impluse Withstand Voltage 5KV Peak
Insulation Resistance DC500V/100MΩ min

 No. 2. Part Number 
Part Number Input  Current Available Output 
ECS36-100 100A Current Outputs/ 20mA, 33.3mA,40mA,50mA,100mA,1A,5A.   Voltage Outputs/ 0.25V,0.333V,0.5V,1V,2V.
ECS36-200 200A
ECS36-300 300A
ECS36-400 400A
ECS36-500 500A
ECS36-600 600A
NotesCurrent Ratio customised are Available. 
------------------------------------------------------------------------------------------------------------------------------------------
Structure & Dimensions
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying


------------------------------------------------------------------------------------------------------------------------------------------
Applications
       1. Current measurement
       2. Monitoring & protection
       3. Energy & sub-metering products
       4. Network equipment
       5. Instruments & sensors
       6. Control systems
    Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying
------------------------------------------------------------------------------------------------------------------------------------------
Related Prodcucts
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying

------------------------------------------------------------------------------------------------------------------------------------------
Company Profile
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying

------------------------------------------------------------------------------------------------------------------------------------------
Package & Transportation
Low Voltage Output Current Transformer Hall Sensor for Energy Metering Instrument Relaying

------------------------------------------------------------------------------------------------------------------------------------------

How to contact:
  •  Echun Electronic Co. Ltd
  •  Address: 3rd floor,B Building, No.88,ShengYe Road, North TianMei,HuangJiang Town,   Dongguan, Guangdong, China  (523757)
  • Tel:  (86 769) 8360 8582
  • Fax:  (86 769) 8360 8337
  • Mobile:  (86) 155 2708 5032
  • Website: dgechun.en.made-in-china.com
-------------------------------------------------------------------------------------------------------------------------------------------
   Really appreciate that you browse our Products.
   Any question please let me know and contact to our online salesman.
  Your trust will be our best encourgement. Look forward to making a coorperation with you.

-------------------------------------------------------------------------------------------------------------------------------------------

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now